Frame size

H630

No. of poles

2P,4P,6P,8P,10P,12P

Rated power

630KW~2500KW

Protection Grade

IP54/IP55

Rated voltage

10kV

Rated Frequency

50HZ/60HZ

Cooling

IC611

Duty

S1

Insulation

F

Mounting

IM B3

Vibration

≤2.3mm/s

Ambient Temperature

-15℃~+40℃

Humidity

Average monthly peak relative humidity is 90%

Note: Motors can be customized according to customer’s requirements.

    Motor Description

    The IC611 motor is equipped with an advanced cooling system that effectively reduces the temperature of the motor during operation. The cooling system utilizes a combination of forced ventilation and water cooling to ensure that the motor remains in good working condition even under high loads. This design greatly extends the service life of the motor and reduces the failure rate.
    The design of IC611 motor takes energy efficiency into full consideration, adopting high-efficiency electromagnetic materials and optimized winding design, so that it can effectively reduce energy consumption during operation. According to the test data, the energy efficiency class of IC611 motor can reach IE3 or IE4, which is in line with the international energy efficiency standards.
    The structural design of IC611 motor has been strictly calculated and tested to ensure its reliability in various harsh environments. The motor's casing is made of high-strength cast iron, which has good corrosion and impact resistance and can adapt to high temperature, high humidity, dust and other complex environments.
    The main technical parameters of IC611 cooled high-voltage three-phase asynchronous motors are as follows:
    -Rated power**: ranging from 100kW to 5000kW
    -Rated voltage**: 3kV, 6kV, 10kV
    -Rated frequency**: 50Hz or 60Hz
    -Insulation class**: Class F or Class H
    -Protection level**: IP55 or IP65
    -Cooling method**: IC611 (forced ventilation + water cooling).

    Outline Dimensions

    11

    Technical Data

    Type

    Rated Power

    kW

    Rated Current

    A

    Rated

    Speed

    r/min

    Efficiency

    %

    Power Factor

    Cosφ

     

    Locked Torque

    Locked

    Current

    Max. Torque

    Load moment of inertia

    Kg.m2

     

    Weight

    Kg

     

     

     

     

     

     

    Rated

    Torque

    Rated

    Current

    Rated Torque

     

     

    YKK6301-2

    2000

    137.8

    2975

    95.2

    0.88

    0.6

    7

    1.8

    92

    9300

    YKK6303-2

    2240

    154

    2975

    95.4

    0.88

    0.6

    7

    1.8

    95

    9700

    YKK6305-2

    2500

    171.9

    2975

    95.4

    0.88

    0.6

    7

    1.8

    98

    10250

    YKK6301-4

    2000

    137.5

    1490

    95.4

    0.88

    0.6

    7

    1.8

    630

    9600

    YKK6303-4

    2240

    153.9

    1490

    95.5

    0.88

    0.6

    7

    1.8

    650

    10200

    YKK6305-4

    2500

    171.8

    1490

    95.5

    0.88

    0.6

    7

    1.8

    670

    10800

    YKK6301-6

    1600

    112.8

    995

    95.2

    0.86

    0.6

    6

    1.8

    1300

    9200

    YKK6302-6

    1800

    126.8

    995

    95.3

    0.86

    0.6

    6

    1.8

    1360

    9650

    YKK6303-6

    2000

    140.7

    995

    95.4

    0.86

    0.6

    6

    1.8

    1400

    10200

    YKK6305-6

    2240

    157.6

    995

    95.4

    0.86

    0.6

    6

    1.8

    1460

    11000

    YKK6302-8

    1120

    82.3

    745

    94.7

    0.83

    0.7

    6

    1.8

    2300

    8600

    YKK6303-8

    1250

    91.7

    745

    94.8

    0.83

    0.7

    6

    1.8

    2400

    9000

    YKK6304-8

    1400

    102.6

    745

    94.9

    0.83

    0.7

    6

    1.8

    2500

    9500

    YKK6305-8

    1600

    117.3

    745

    94.9

    0.83

    0.7

    6

    1.8

    2600

    10000

    YKK6301-10

    900

    69.1

    595

    94

    0.8

    0.7

    6

    1.8

    2600

    9100

    YKK6302-10

    1000

    76.7

    595

    94.1

    0.8

    0.7

    6

    1.8

    2700

    9400

    YKK6303-10

    1120

    85.8

    595

    94.2

    0.8

    0.7

    6

    1.8

    2850

    9700

    YKK6304-10

    1250

    95.8

    595

    94.2

    0.8

    0.7

    6

    1.8

    3200

    10100

    YKK6305-10

    1400

    107.1

    595

    94.3

    0.8

    0.7

    6

    1.8

    3590

    10600

    YKK6301-12

    630

    52.8.

    495

    93.1

    0.74

    0.7

    6

    1.8

    2900

    9050

    YKK6302-12

    710

    59.4

    495

    93.3

    0.74

    0.7

    6

    1.8

    3000

    9400

    YKK6303-12

    800

    66.5

    495

    93.8

    0.74

    0.7

    6

    1.8

    3150

    9800

    YKK6304-12

    900

    74.9

    495

    93.8

    0.74

    0.7

    6

    1.8

    3320

    10200

    YKK6305-12

    1000

    83.2

    495

    93.8

    0.74

    0.7

    6

    1.8

    3700

    10600

    Application

    description1