Leave Your Message
YXKK-560-2/4/6/8/10/12 6kV Wound Air Cooling 3-Phase Asynchronous Motor

Products

YXKK-560-2/4/6/8/10/12 6kV Wound Air Cooling 3-Phase Asynchronous Motor

Frame size

H560

No. of poles

2P,4P,6P,8P,10P,12P

Rated power

500KW~2000KW

Protection Grade

IP54/IP55

Rated voltage

6kV

Rated Frequency

50HZ/60HZ

Cooling

IC611

Duty

S1

Insulation

F

Mounting

IM B3

Vibration

≤2.3mm/s

Ambient Temperature

-15℃~+40℃

Humidity

Average monthly peak relative humidity is 90%

Note: Motors can be customized according to customer’s requirements.

    Motor Description

    Regular maintenance is essential to ensure the long-term stable operation of the IM B3 mounted high voltage motor. The following are some suggestions for maintenance:
    Regularly conduct a comprehensive inspection of the motor, including electrical connections, insulation status, bearing lubrication, etc., to ensure that all components work properly.
    Keep the exterior of the motor clean and regularly clean dust and dirt to avoid affecting the heat dissipation performance.
    Regularly check and change the lubricating oil of the motor to ensure good lubrication of the bearings and reduce wear and tear.
    Monitor the operating temperature of the electric motor to ensure that it is within the safe range and to avoid failures caused by overheating.
    Once abnormal noise, vibration or high temperature are found in the motor, it should be shut down immediately for inspection and timely troubleshooting.
    IM B3 mounted high voltage motors have become an indispensable and important equipment in modern industry by virtue of their high efficiency, durability, low noise and other advantages. Its wide range of applications and flexible installation methods enable IM B3 motors to meet the needs of different customers. Regular maintenance can effectively extend the service life of the motor and ensure its stability and reliability in various industrial applications. Choosing IM B3 to install high voltage motors will provide strong power support for your production.

    Outline Dimensions

    26

    Technical Data

    Type

    Rated Power

    kW

    Rated Current

    A

    Rated

    Speed

    r/min

    Efficiency

    %

    Power Factor

    Cosφ

     

    Locked Torque

    Locked

    Current

    Max. Torque

    Load moment of inertia

    Kg.m2

     

    Weight

    Kg

     

     

     

     

     

     

    Rated

    Torque

    Rated

    Current

    Rated Torque

     

     

    YXKK5601-2

    1600

    182.2

    2985

    96

    0.88

    0.6

    7

    1.8

    78

    6750

    YXKK5602-2

    1800

    205

    2985

    96

    0.88

    0.6

    7

    1.8

    82

    7000

    YXKK5603-2

    2000

    227.3

    2985

    96.2

    0.88

    0.6

    7

    1.8

    86

    7250

    YXKK5601-4

    1600

    182.4

    1490

    95.9

    0.88

    0.6

    6.5

    1.8

    430

    7363

    YXKK5602-4

    1800

    205

    1490

    96

    0.88

    0.6

    6.5

    1.8

    490

    7855

    YXKK5603-4

    2000

    227.6

    1490

    96.1

    0.88

    0.6

    6.5

    1.8

    540

    8099

    YXKK5601-6

    1120

    132.6

    990

    95.6

    0.85

    0.7

    6.5

    1.8

    970

    7420

    YXKK5602-6

    1250

    146

    990

    95.8

    0.86

    0.7

    6.5

    1.8

    1100

    7975

    YXKK5603-6

    1400

    163.3

    990

    95.9

    0.86

    0.7

    6.5

    1.8

    1210

    8208

    YXKK5601-8

    800

    98.6

    740

    95.2

    0.82

    0.7

    6

    1.8

    1350

    6949

    YXKK5602-8

    900

    108.2

    740

    95.3

    0.84

    0.7

    6

    1.8

    1420

    7242

    YXKK5603-8

    1000

    120.1

    740

    95.4

    0.84

    0.7

    6

    1.8

    1560

    7655

    YXKK5601-10

    710

    92.7

    590

    94.5

    0.78

    0.7

    6

    1.8

    1840

    7040

    YXKK5602-10

    800

    101.5

    590

    94.8

    0.8

    0.7

    6

    1.8

    1860

    7694

    YXKK5603-10

    900

    114.1

    595

    94.9

    0.8

    0.7

    6

    1.8

    2150

    7702

    YXKK5601-12

    500

    69

    490

    94.2

    0.74

    0.7

    6

    1.8

    2258

    6909

    YXKK5602-12

    560

    75.2

    490

    94.3

    0.76

    0.7

    6

    1.8

    2259

    7048

    YXKK5603-12

    630

    84.5

    490

    94.4

    0.76

    0.7

    6

    1.8

    2300

    7606

    Application